Sperm counting chamber with grid |
|
Product name:Sperm counting chamber with grid |
|
Item: |
|
Details: |
|
Note: To reduce the temperature on the analysis of the impact of sperm motility, sperm count board proposes to place the company specializes in supporting sperm microscope heating stage HS-70S preheated hot plate for 15-20 minutes. - Sperm counting chamber with grid is used for instrument counting - Sperm counting chamber, no grid is use for manual counting 1.Application Sperm counting chamber is widely used in the Fluid samples of the routine examination and measurement inspection, such as semen, prostate, cervical mucus and so on. 2.Main technical parameters 1) exterior dimensions:76×36×7 2) The grid sperm count plate: 3) The computer scanning with no grid sperm counts board 4) The space between pedestal of count plate and cover plate is 5) precision error: The clearance at 37 degrees is ±0.001 (4 red light wavelengths) 3.Usage way 1) Φ 2) Disinfecting the platform using medicine alcohol 3) Dropping the inspected body fluid on theround platform 4) Close the cover and insert it to the microscope platform of constant temperature. Then observe it using 20 X microscope. 5) In the microscope visual system, connect digital camera with computer, and then the computer scanning count work ( still using 20 X optical lens). 4.Announcements 1) This product is a check try products with high precision glass and cannot be hitted. 2) Do not use hard thing to blow the surface of the platform. 3) It should be cleaned up without using and put it in special box after disinfection 4) Disinfection method:clean up with clear water first then wipe with medicine alcohol , notice that water temperature can not high than 5.The range of repairing 1) Count board: 1 year (according to the type of bord) 2) The gem fall off (but not lost) 3) The clearance is too high and the normal range is 0.01 + /-0.002. (Can not be judged by visual inspection) 4) The piece need to be fixed , when it come back to the factory, the type of the bord should be accordance with the type in certificate.After repairing, return it as the former type. 6.The following circumstances are not in guaranteed repair range: 1) The counting plate belongs to senior glass product, vulnerable so please operate it according to instruments. 2) It appears scratch, broken edge glass, the loss of the stones because of improper use. 3) The gem fall off due to the temperature deviation (more than 4) It appears clearance after using 1 year.o reduce the temperature on the analysis of the impact of sperm motility, |
|
←[Previous:] |
Related Products : |
|
|